title: "Does stacking two Peltier modules make it colder?"
topic: "Peltier stacks"
answer: "Not at the same voltage. Simulated on a fan heatsink, one TEC1-12706 at 12 V takes its cold face to −29.2 °C. Stack a second one on top, each wired straight to 12 V, and the cold face reaches −29.4 °C, on 112 W instead of 50 W. Run the top one at 5 V and the pair reaches −48.6 °C on 61 W."
url: "https://nearfieldnotes.com/notes/peltier-stack/"
site: "Near Field Notes"
author: "Michael Walker"
note: 41
family: "Power"
published: "2026-11-15"
revised: "2026-11-15"
revision: 1
video: "https://nearfieldnotes.com/videos/peltier-stack/"
---

Note 41 · [Power](https://nearfieldnotes.com/families/power/) · Rev 1 · [Watch the video · 2:53](https://nearfieldnotes.com/videos/peltier-stack/)

Peltier stacks

# Does stacking two Peltier modules make it colder?

**Short answer:** Not at the same voltage. Simulated on a fan heatsink, one TEC1-12706 at 12 V takes its cold face to −29.2 °C. Stack a second one on top, each wired straight to 12 V, and the cold face reaches −29.4 °C, on 112 W instead of 50 W. Run the top one at 5 V and the pair reaches −48.6 °C on 61 W.

The bottom module has to carry all the heat the top one burns. At 12 V that keeps the joint between them at 39.6 °C, warmer than the room.

A stack pays off when each stage is weaker than the one under it: a lower voltage on the top module, or fewer legs in a factory part.

**Note 41’s opening figure: Two modules, three ways.** Each module drawn from its cold face’s temperature to its hot face’s

![Note 41’s opening figure: Two modules, three ways](https://nearfieldnotes.com/notes/peltier-stack/fig-opening.png)

*What the figure shows:* Two TEC1-12706 Peltier modules on a fan heatsink in a 25 degree C room, simulated, drawn as bars from each module's cold face temperature to its hot face temperature. One module at 12 V: cold face minus 29.2 degrees C, hot face 39.9, 50 W. Two stacked, both at 12 V: cold face minus 29.4, the joint between them 39.6, the bottom's hot face 58.6, 112 W. Top at 5 V and bottom at 12 V: cold face minus 48.6, joint minus 16.1, hot face 43.4, 61 W.

Simulated on a fan heatsink in a 25 °C room, nothing on the cold face. The top module, or the only one, is blue, and the bottom one orange. The chart ends with all three side by side.

## Two TEC1-12706s on a fan heatsink

*40 mm, 127 pairs of legs*

The TEC1-12706 is the common 40 mm Peltier module: 127 pairs of [bismuth telluride](https://nearfieldnotes.com/glossary/#g-bismuth-telluride) legs between two ceramic faces. Current through the legs carries heat from one face to the other. [Note 39](https://nearfieldnotes.com/notes/peltier-pwm/) shows how one works and how to drive it.

Here one sits on a fan heatsink that warms 0.30 °C for every watt it takes, in a 25 °C room. Nothing sits on its cold face and no air reaches it, so each number is the coldest the setup can get.

Then a second, identical module goes on top of the first, with a film of grease between them, each on its own supply.

**Fig. 41a: One module, and two stacked.**

![Fig. 41a: One module, and two stacked](https://nearfieldnotes.com/notes/peltier-stack/fig-41a.png)

*What the figure shows:* Figure 41a: two identical fan heatsinks rendered side by side, each a finned aluminum block lying base up on a fan. On the left one, a single 40 mm square Peltier module sits on the base, its red and black leads running off the edge. On the right one, two of the same modules sit stacked, one on the other, with two pairs of leads.

Rendered. The modules are 40 mm square and 3.8 mm thick. The heatsink is 110 mm across, with a 92 mm fan under its fins.

Stacked, the pair has three faces that matter: the top module’s cold face, the joint where the two meet, and the bottom module’s hot face on the heatsink.

Each module is one [stage](https://nearfieldnotes.com/glossary/#g-stage) of the stack. The top one cools the cold face, and the bottom one cools the top one.

**Fig. 41b: The stack, cut open.**

![Fig. 41b: The stack, cut open](https://nearfieldnotes.com/notes/peltier-stack/fig-41b.png)

*What the figure shows:* Figure 41b: the two stacked modules rendered cut open through a row of legs, seen from the side, on the heatsink's base. Each module is two white ceramic faces with a row of legs between them, joined by copper tabs. The top module's upper face is the cold face, the two meet at the joint, and the bottom module's lower face, the hot face, sits on the heatsink.

Rendered, cut through a row of legs. Copper tabs join the legs in pairs, top and bottom.

## Why a second module on 12 V adds nothing

*Joint at 39.6 °C*

At 12 V the top module draws 49.9 W. All of it, plus whatever it pulls off its cold face, lands on the bottom module.

So the bottom module is busy just keeping up. It draws 62.2 W carrying that heat down to the heatsink, and the joint settles at 39.6 °C, warmer than the room.

The top module works down from there. Its 69.0 °C drop gets the cold face only back to −29.4 °C. One module alone, its hot face on the heatsink at 39.9 °C, already got to −29.2 °C.

**Fig. 41c: What each module draws.**

![Fig. 41c: What each module draws](https://nearfieldnotes.com/notes/peltier-stack/fig-41c.png)

*What the figure shows:* Figure 41c: the power each module draws on the fan heatsink, simulated, as stacked bars. One module at 12 V draws 49.8 W. Two stacked at 12 V: the top draws 49.9 W and the bottom 62.2 W, 112.0 W in all. The same two in series across 12 V: the top draws 13.1 W and the bottom 12.4 W, 25.5 W in all. Top at 5 V, bottom at 12 V: the top draws 9.6 W and the bottom 51.8 W, 61.5 W in all.

Simulated. In series across 12 V each module gets about 6 V. With nothing on the cold face, the total is also the heat the heatsink carries away.

**The numbers**

On the fan heatsink, 25 °C room, nothing on the cold face. From the model, not a bench.

| Case | Top (or only) module | Bottom module | In all | Cold face | On the heatsink |
|---|---|---|---|---|---|
| One module, 12 V | 12 V, 4.15 A, 49.8 W | None | 49.8 W | −29.2 °C | 39.9 °C |
| Two stacked, each on 12 V | 12 V, 4.16 A, 49.9 W | 12 V, 5.18 A, 62.2 W | 112.0 W | −29.4 °C | 58.6 °C |
| Two stacked, in series across 12 V | 6.2 V, 2.12 A, 13.1 W | 5.8 V, 2.12 A, 12.4 W | 25.5 W | −34.8 °C | 32.6 °C |
| Top 5 V, bottom 12 V | 5 V, 1.93 A, 9.6 W | 12 V, 4.32 A, 51.8 W | 61.5 W | −48.6 °C | 43.4 °C |

Two modules, each on 12 V

### −29.4 °C on 112 W

**Field marks.** The cold face sits within a few tenths of a degree of one module’s, on more than twice the power. The joint is warmer than the room, and the face on the heatsink reaches 58.6 °C.

**Look-alike.** The same two wired in series across 12 V: −34.8 °C on 25 W, 5.6 °C colder than one module.

**Range.** Let room air reach the cold face and both warm a little, to −27.7 °C for one module and −27.2 °C for the pair. The gap stays under a degree.

**Habitat.** Stacks built by hand from two of the same module, each wired straight across one 12 V supply.

## Two in series on one 12 V supply

*−34.8 °C on 25 W*

Wire the same two in series across one 12 V supply and the pair reaches −34.8 °C on 25 W. That is 5.6 °C colder than one module at 12 V, on about half the power. It is still far short of the −48.6 °C the pair reaches with its top on 5 V.

In series the two carry one current, so they act as one module with legs twice as tall. Each gets about 6 V, so the pair draws less, and the heatsink runs cooler: 32.6 °C against 39.9 °C under one module at 12 V.

So the gain is the heatsink’s, not the stack’s. Hold the hot face at 27 °C, the way datasheets rate modules, and it shrinks to under a degree: at their best currents one module bottoms out at −43.5 °C, the pair at −44.4 °C and a module with legs twice as tall at −43.5 °C.

Back on the fan heatsink, at their best currents, the pair reaches −37.0 °C against −29.7 °C for one module, on 40 W against 63 W. One module with legs twice as tall gets −36.5 °C, nearly the same.

A correction to the video: it says the pair in series is no colder than one module. That is within a degree of true with the hot face fixed at 27 °C. On the video’s own fan heatsink the pair is 5.6 °C colder, as above.

**Fig. 41d: Cold face against current, on the fan heatsink.**

![Fig. 41d: Cold face against current, on the fan heatsink](https://nearfieldnotes.com/notes/peltier-stack/fig-41d.png)

*What the figure shows:* Figure 41d: the cold face against the current through each module on the fan heatsink, simulated, for one module, for two stacked in series, and for one module with legs twice as tall. One module bottoms out at minus 29.7 degrees C at 4.71 A. The two in series bottom out at minus 37.0 at 2.72 A, and the tall-legged module traces nearly the same curve, bottoming out at minus 36.5 at 2.73 A.

Simulated. Both modules of the pair carry the same current. The dashed line is one module with legs twice as tall. It runs best on the same current as the pair.

**The numbers**

Each at its own best current. Fan: the fan heatsink in a 25 °C room. Held 27 °C: the hot face held at 27 °C, as datasheets rate modules. From the model, not a bench.

| Stack | Fan: coldest | at | drawing | Held 27 °C: coldest | at | drawing |
|---|---|---|---|---|---|---|
| One module | −29.7 °C | 4.71 A | 63.0 W | −43.5 °C | 6.46 A | 103.9 W |
| Two in series | −37.0 °C | 2.72 A | 40.0 W | −44.4 °C | 3.21 A | 52.4 W |
| One, legs twice as tall | −36.5 °C | 2.73 A | 40.0 W | −43.5 °C | 3.23 A | 51.9 W |

## The top stage has to be the weak one

*Top at 5 V*

The fix is to make the top module the weak one. On 5 V it draws only 9.6 W, so the bottom module has little to carry and pulls the joint down to −16.1 °C.

From there the top module’s own drop reaches −48.6 °C, 19.5 °C colder than one module, on 61 W in all.

Sweep the top module’s voltage with the bottom on 12 V, and the cold face bottoms out at −48.7 °C at 5.25 V. So 5 V is about as good as it gets.

Higher, the top burns more than it lifts. At 8 V the joint is back above freezing, at 3.1 °C, and the cold face is up to −45.0 °C.

Tuning both supplies buys less than a degree more: −49.3 °C with the top at 5.25 V and the bottom at 13.5 V, on 77 W.

Builders of Peltier cloud chambers use the same recipe. They put the line near −25 °C: colder than that, alcohol vapor shows the tracks of particles passing through. One published build runs a 12710 module underneath on 12 V and a 12709 on top on 5 V, and warns: “do -not- try running the top peltier at 12v.”

**Fig. 41e: The top module’s voltage.**

![Fig. 41e: The top module’s voltage](https://nearfieldnotes.com/notes/peltier-stack/fig-41e.png)

*What the figure shows:* Figure 41e: two charts sharing one axis, the top module's voltage from 0.5 to 12 V with the bottom module on 12 V, on the fan heatsink, simulated. Upper chart, the cold face: minus 32.8 degrees C at 0.5 V, falling to minus 48.6 at 5 V, the coldest region, then rising to minus 29.4 at 12 V. Lower chart, the power both modules draw: 50 W at 0.5 V, 61 W at 5 V and 112 W at 12 V.

Simulated on the fan heatsink. Past about 5 V the cold face warms while the power keeps climbing.

**The numbers**

Bottom module on 12 V, fan heatsink, 25 °C room, nothing on the cold face. From the model, not a bench.

| Top | Cold face | Joint | Hot face | Top draws | Bottom draws | In all |
|---|---|---|---|---|---|---|
| 0.5 V | −32.8 °C | −29.0 °C | 40.0 °C | 0.1 W | 49.8 W | 49.9 W |
| 1.0 V | −36.0 °C | −28.7 °C | 40.1 °C | 0.4 W | 49.9 W | 50.2 W |
| 1.5 V | −38.9 °C | −28.0 °C | 40.2 °C | 0.8 W | 49.9 W | 50.8 W |
| 2.0 V | −41.4 °C | −27.1 °C | 40.5 °C | 1.5 W | 50.0 W | 51.5 W |
| 2.5 V | −43.5 °C | −25.9 °C | 40.8 °C | 2.4 W | 50.2 W | 52.5 W |
| 3.0 V | −45.2 °C | −24.5 °C | 41.1 °C | 3.4 W | 50.3 W | 53.8 W |
| 3.5 V | −46.6 °C | −22.8 °C | 41.6 °C | 4.7 W | 50.6 W | 55.3 W |
| 4.0 V | −47.6 °C | −20.8 °C | 42.1 °C | 6.2 W | 51.0 W | 57.1 W |
| 4.5 V | −48.3 °C | −18.6 °C | 42.8 °C | 7.8 W | 51.4 W | 59.2 W |
| 5.0 V | −48.6 °C | −16.1 °C | 43.4 °C | 9.6 W | 51.8 W | 61.5 W |
| 5.5 V | −48.7 °C | −13.4 °C | 44.2 °C | 11.6 W | 52.3 W | 63.9 W |
| 6.0 V | −48.4 °C | −10.5 °C | 45.0 °C | 13.8 W | 52.8 W | 66.6 W |
| 6.5 V | −47.9 °C | −7.4 °C | 45.8 °C | 16.1 W | 53.4 W | 69.4 W |
| 7.0 V | −47.2 °C | −4.1 °C | 46.8 °C | 18.5 W | 54.0 W | 72.5 W |
| 7.5 V | −46.2 °C | −0.6 °C | 47.7 °C | 21.1 W | 54.7 W | 75.7 W |
| 8.0 V | −45.0 °C | 3.1 °C | 48.7 °C | 23.7 W | 55.4 W | 79.1 W |
| 9.0 V | −42.0 °C | 11.2 °C | 51.0 °C | 29.6 W | 56.9 W | 86.5 W |
| 10.0 V | −38.4 °C | 19.9 °C | 53.3 °C | 35.9 W | 58.5 W | 94.5 W |
| 11.0 V | −34.2 °C | 29.4 °C | 55.9 °C | 42.7 W | 60.3 W | 103.0 W |
| 12.0 V | −29.4 °C | 39.6 °C | 58.6 °C | 49.9 W | 62.2 W | 112.0 W |

## Factory stacks do it with size

*127, 71, 31, 17 and 8 pairs*

A factory [multistage cooler](https://nearfieldnotes.com/glossary/#g-multistage-cooler) makes the top stage weak with size instead. Each stage up has fewer pairs of legs, so it draws less, and one supply feeds them all in series.

Thermonamic’s family is built on the 12706: 127 pairs at the bottom, then 71, 31, 17 and 8. With nothing on top, its sheets rate them 70, 88, 104, 116 and 128 °C below a 27 °C hot face.

**Fig. 41f: One stage to five.**

![Fig. 41f: One stage to five](https://nearfieldnotes.com/notes/peltier-stack/fig-41f.png)

*What the figure shows:* Figure 41f: five Peltier coolers of one 40 mm family rendered in a row, from one stage to five. Each is a stack of white ceramic faces with rows of legs between them, every stage up smaller than the one under it, so the five-stage one rises like a stepped pyramid to a small square top. Each has a red and a black lead.

Rendered to the sizes on Thermonamic’s sheets. The top stages shrink from 40 mm square to 10 mm.

**The numbers**

Thermonamic’s TEC1-12706 and its TEC2 to TEC5 parts. Every bottom stage is the 12706’s 127 pairs.

| Stages | Pairs of legs, bottom to top | Rated current |
|---|---|---|
| 1 | 127 | 6.1 A |
| 2 | 127 / 71 | 4.2 A |
| 3 | 127 / 71 / 31 | 3.4 A |
| 4 | 127 / 71 / 31 / 17 | 3.4 A |
| 5 | 127 / 71 / 31 / 17 / 8 | 3.6 A |

This page builds all five from the one-module model, each stage with the 12706’s legs and the sheet’s number of pairs. The only thing fitted per part is a leg size that matches its rated current, and that leaves the drop alone.

The model lands within two degrees of each sheet: 70.5 °C for one stage, up to 126.2 °C for five.

The gains shrink: 18 °C for the second stage, then 16, 12 and 12.

**Fig. 41g: How far below the hot face, sheet and model.**

![Fig. 41g: How far below the hot face, sheet and model](https://nearfieldnotes.com/notes/peltier-stack/fig-41g.png)

*What the figure shows:* Figure 41g: how far below a 27 degree C hot face each of the five coolers gets with nothing on it. Bars: Thermonamic's datasheets, 70, 88, 104, 116, 128 degrees for one to five stages. Ticks: this page's model, 70.5, 87.9, 105.1, 116.0, 126.2.

Bars: Thermonamic’s sheets, in dry air or nitrogen. Ticks: this page’s model. The table adds each part’s rated voltage and heat, which the model gets within 6% and 10%.

**The numbers**

At a 27 °C hot face. The model is the one-module model with each part’s pairs of legs, and one leg size per part fitted so its best current lands on the sheet’s Imax; that fit leaves the drop alone.

| Stages | Drop, sheet | Drop, model | Vmax, sheet | Vmax, model | Qmax, sheet | Qmax, model |
|---|---|---|---|---|---|---|
| 1 | 70 °C | 70.5 °C | 16 V | 16.1 V | 61.4 W | 59.0 W |
| 2 | 88 °C | 87.9 °C | 15.4 V | 16.2 V | 28.2 W | 28.4 W |
| 3 | 104 °C | 105.1 °C | 15.8 V | 16.0 V | 13.2 W | 13.3 W |
| 4 | 116 °C | 116.0 °C | 14.5 V | 15.1 V | 9.1 W | 8.2 W |
| 5 | 128 °C | 126.2 °C | 14.4 V | 14.5 V | 5.22 W | 4.9 W |

## Each stage carries every stage above it

*−82.4 °C with half a watt on top*

Here is the four-stage part with 0.5 W on its cold face, at its rated 3.4 A. It holds the cold face at −82.4 °C.

The top stage lifts the half watt and burns 2.7 W doing it, so the stage below must lift 3.2 W. Then 8.7 W, then 23.7 W.

**Fig. 41h: The four-stage part, cut open.**

![Fig. 41h: The four-stage part, cut open](https://nearfieldnotes.com/notes/peltier-stack/fig-41h.png)

*What the figure shows:* Figure 41h: the four-stage cooler rendered cut open, seen from the side: four layers of legs between five ceramic faces, each layer narrower than the one under it, with 127, 71, 31 and 17 pairs of legs from the bottom up, joined by small wire links at the left.

Rendered from the sizes on Thermonamic’s sheet for its TEC4-127-71-31-17-03. The numbers are each stage’s pairs of legs. Leg sizes are this page’s estimate.

Half a watt goes in at the top, and 51.7 W comes out the bottom.

That is why the stages shrink going up. Each one only has to be big enough for what lands on it, and the bottom one carries everything.

**Fig. 41i: Heat crossing each face.**

![Fig. 41i: Heat crossing each face](https://nearfieldnotes.com/notes/peltier-stack/fig-41i.png)

*What the figure shows:* Figure 41i: the heat crossing each face of the four-stage cooler with 0.5 W on its cold face, at 3.4 A, simulated. Cold face at minus 82 degrees C, 0.5 W. Face 2 at minus 55 degrees C, 3.2 W, after the stage above burns 2.7 W. Face 3 at minus 32 degrees C, 8.7 W, after the stage above burns 5.4 W. Face 4 at minus 1 degrees C, 23.7 W, after the stage above burns 15.0 W. Hot face at 27 degrees C, 51.7 W into the heatsink.

Simulated, hot face held at 27 °C. Each face passes down what the stage above lifted plus what it burned.

**The numbers**

Thermonamic’s four-stage part at 3.4 A, its rated current, hot face held at 27 °C. From the model, not a bench.

| Stage, top down | Its faces | Lifts | Burns | Passes down |
|---|---|---|---|---|
| 1, 17 pairs | −82.4 °C to −55.2 °C | 0.50 W | 2.71 W | 3.21 W |
| 2, 31 pairs | −55.2 °C to −31.6 °C | 3.21 W | 5.44 W | 8.65 W |
| 3, 71 pairs | −31.6 °C to −1.0 °C | 8.65 W | 15.01 W | 23.66 W |
| 4, 127 pairs | −1.0 °C to 27.0 °C | 23.66 W | 28.08 W | 51.74 W |

## Load decides the stage count

*One stage wins past about 9 W*

That growth is why the load decides how many stages to use. Each extra stage multiplies what the bottom one must carry, so a deep stack warms fast once it has a real load on it.

At 1 W the five-stage part gets no colder than the four: −74.7 °C against −75.7 °C.

At 10 W one plain module beats them all, at −32.2 °C. Two stages manage −30.9 °C, and three only −0.8 °C.

**Fig. 41j: Cold face against load, one stage to five.**

![Fig. 41j: Cold face against load, one stage to five](https://nearfieldnotes.com/notes/peltier-stack/fig-41j.png)

*What the figure shows:* Figure 41j: the cold face of five Peltier coolers, one stage to five, against the heat load on the cold face from 0 to 12 W, with the hot face held at 27 degrees C, simulated. With no load they reach minus 43.5, minus 60.9, minus 78.1, minus 89.0, minus 99.3 degrees C. More stages warm faster with load: the five-stage line crosses the four-stage one near 0.9 W, the four crosses the three near 1.8 W, the three crosses the two near 3.8 W, and past about 9.3 W one stage is coldest.

Simulated, each part at its best current, never past its rated current. A line that leaves the top of the chart has passed 20 °C.

## Load the cold face yourself

*0 to 12 W*

Set the heat on the cold face. Each bar runs down from the 27 °C hot face to where that part’s cold face settles, and the coldest is darkest.

**Note 41’s explorer: Cold face, one stage to five.**

![Note 41’s explorer: Cold face, one stage to five](https://nearfieldnotes.com/notes/peltier-stack/fig-explore.png)

*What the figure shows:* The cold face of each of five Peltier coolers, from one stage to five, for the chosen heat load on the cold face, with the hot face held at 27 degrees C, simulated. Each bar runs down from the hot face to the cold face, and the coldest is darkest.

Each load is its own run of Thermonamic’s five parts, each at its best current, never past its rated current.

**The numbers**

Coldest face at each part’s best current, never above its sheet’s Imax; hot face held at 27 °C.

| Load | 1 stage | 2 | 3 | 4 | 5 |
|---|---|---|---|---|---|
| 0 W | −43.5 °C | −60.9 °C | −78.1 °C | −89.0 °C | −99.3 °C |
| 0.25 W | −43.2 °C | −60.2 °C | −76.3 °C | −85.7 °C | −93.2 °C |
| 0.5 W | −42.9 °C | −59.4 °C | −74.4 °C | −82.4 °C | −87.1 °C |
| 1 W | −42.4 °C | −58.0 °C | −70.7 °C | −75.7 °C | −74.7 °C |
| 1.5 W | −41.8 °C | −56.5 °C | −66.9 °C | −68.9 °C | −62.1 °C |
| 2 W | −41.2 °C | −55.0 °C | −63.1 °C | −62.1 °C | −49.3 °C |
| 3 W | −40.1 °C | −52.0 °C | −55.5 °C | −48.3 °C | −23.5 °C |
| 4 W | −39.0 °C | −49.0 °C | −47.9 °C | −34.4 °C | 2.6 °C |
| 5 W | −37.9 °C | −46.0 °C | −40.2 °C | −20.3 °C | Warmer than 27 °C |
| 7 W | −35.6 °C | −39.9 °C | −24.6 °C | 8.4 °C | Warmer than 27 °C |
| 10 W | −32.2 °C | −30.9 °C | −0.8 °C | Warmer than 27 °C | Warmer than 27 °C |
| 12 W | −29.9 °C | −24.8 °C | 15.9 °C | Warmer than 27 °C | Warmer than 27 °C |

## Stages save power too

*0.5 W at −40 °C*

Where the load is small enough, stages also save power. A single stage holding 0.5 W at −40 °C is near its limit and runs hard.

It takes 58.9 W with one stage, 16.4 W with two, 7.6 W with three and 5.8 W with four. The fifth stage saves almost nothing more: 5.7 W.

**Fig. 41k: Power to hold 0.5 W at −40 °C.**

![Fig. 41k: Power to hold 0.5 W at −40 °C](https://nearfieldnotes.com/notes/peltier-stack/fig-41k.png)

*What the figure shows:* Figure 41k: the power each of the five coolers needs to hold 0.5 W at minus 40 degrees C with its hot face at 27 degrees C, simulated: 58.9 W with 1 stage, 16.4 W with 2 stages, 7.6 W with 3 stages, 5.8 W with 4 stages, 5.7 W with 5 stages.

Simulated, hot face held at 27 °C, each part on the least current that holds it.

**The numbers**

Least power to hold 0.5 W there, every stage on one current, hot face held at 27 °C. From the model, not a bench.

| Cold face | 1 stage | 2 | 3 | 4 | 5 |
|---|---|---|---|---|---|
| −20 °C | 15.6 W | 5.9 W | 3.1 W | 2.5 W | 2.7 W |
| −30 °C | 28.6 W | 10.0 W | 4.9 W | 3.9 W | 3.9 W |
| −40 °C | 58.9 W | 16.4 W | 7.6 W | 5.8 W | 5.7 W |
| −50 °C | Can’t | 27.8 W | 11.7 W | 8.6 W | 8.1 W |
| −60 °C | Can’t | Can’t | 18.3 W | 12.8 W | 11.6 W |
| −70 °C | Can’t | Can’t | 31.7 W | 19.7 W | 17.1 W |
| −80 °C | Can’t | Can’t | Can’t | 35.7 W | 27.2 W |

## What sets the floor

*The legs, and the leaks*

Two things set how cold a stack can get. The first is the legs. Bismuth telluride gets worse as it gets colder.

Its [figure of merit, ZT](https://nearfieldnotes.com/glossary/#g-zt), falls from 0.83 near room temperature to 0.31 at −100 °C, less than half. The coldest stages work with the weakest material. [Note 40](https://nearfieldnotes.com/notes/peltier-generator/) shows what the same number does to a generator’s efficiency.

**Fig. 41l: ZT against temperature.**

![Fig. 41l: ZT against temperature](https://nearfieldnotes.com/notes/peltier-stack/fig-41l.png)

*What the figure shows:* Figure 41l: the figure of merit ZT of the bismuth telluride in this page's model against the legs' temperature, from minus 100 to plus 57 degrees C. It rises steadily, from 0.31 at minus 100 degrees C to 0.83 at 27 degrees C.

The material in this page’s model.

**The numbers**

The model’s material: the TEC1-12706’s datasheet fit above −8 °C, Ferrotec’s published curves below, scaled to meet it.

| Legs at | ZT |
|---|---|
| −100 °C | 0.31 |
| −90 °C | 0.36 |
| −80 °C | 0.41 |
| −70 °C | 0.46 |
| −60 °C | 0.51 |
| −50 °C | 0.56 |
| −40 °C | 0.60 |
| −30 °C | 0.64 |
| −20 °C | 0.68 |
| −10 °C | 0.70 |
| 0 °C | 0.73 |
| 10 °C | 0.77 |
| 20 °C | 0.80 |
| 30 °C | 0.84 |
| 40 °C | 0.88 |
| 50 °C | 0.92 |

The second is leaks. The top stage is tiny and lifts little, so any heat that sneaks in costs it degrees.

By TEC Microsystems’ figures, still air or nitrogen costs a four-stage cooler about 18 °C against a vacuum, and xenon about 10. So deep stacks are sealed in a vacuum or a heavy gas.

The coldest catalog part found for this page is Marlow’s MI6030, six stages: 133 °C below its hot side, in a vacuum, with nothing on it.

**Fig. 41m: What still air costs.**

![Fig. 41m: What still air costs](https://nearfieldnotes.com/notes/peltier-stack/fig-41m.png)

*What the figure shows:* Figure 41m: how much of a cooler's coldest drop still dry air or nitrogen costs against a vacuum, by stage count, from TEC Microsystems: 4 degrees C with 1 stage, 9 degrees C with 2 stages, 12 degrees C with 3 stages, 18 degrees C with 4 stages.

From TEC Microsystems: the drop lost in still dry air or nitrogen, against the same cooler in a vacuum.

## Who pays for four stages

*9 times the price of one*

At one shop on one day, a 40 mm single-stage module was $24.25 and a four-stage part $215.90. It pays wherever a sensor makes milliwatts of heat and works better cold.

Two stages in a 4.1 g can cool the X-ray detectors in portable analyzers that read what a metal is made of. Amptek seals its cans with a vacuum inside and calls the cooling “critical to the development of portable XRF analyzers.”

Four stages hold infrared detectors at −78 °C. Thorlabs lists one at $4,932.27, $962.01 more than the same detector with no cooler.

And six stages hold the infrared detector in Hubble’s Wide Field Camera 3 at 145 K, −128 °C.

**Fig. 41n: Two stages in a detector can.**

![Fig. 41n: Two stages in a detector can](https://nearfieldnotes.com/notes/peltier-stack/fig-41n.png)

*What the figure shows:* Figure 41n: a round metal detector can rendered with its front cut away. On its gold header, among the pins, sits a small two-stage Peltier cooler, and on top of that a square detector chip under a round window in the can's lid.

Rendered for this page, in the shape of the TO-8 cans cooled detectors come in. The parts inside are drawn, not copied from a maker’s drawing.

**Figure: Where stacks work, and what they cost.**

Fig. 41o

| Stages | Where | Cold end | Price |
|---|---|---|---|
| 2, hand-stacked | Hobby cloud chambers: a 12710 module on 12 V under a 12709 on 5 V | Below about −25 °C | $23.25 to $34.20 a module |
| 2 | X-ray detectors in portable analyzers, sealed with a vacuum inside a 4.1 g can | 220 to 230 K, about −50 °C | Not public |
| 2 | Factory two-stage module, 92 °C rated drop | – | $74.75 |
| 4 | Infrared detectors (Thorlabs VML10T4) | −78 °C, 195 K | $4,932.27, against $3,970.26 uncooled |
| 4 | Factory four-stage module, 115 °C, 9.1 W | – | $215.90 |
| 5 | Factory five-stage module, 128 °C, 9.75 W | – | $295.00 |
| 6 | Hubble’s Wide Field Camera 3, infrared detector | 145 K, −128 °C | – |

Prices read on 12 November 2026, for one piece: Custom Thermoelectric for the modules, Thorlabs for the detector. The cloud-chamber line is one published build, the X-ray line Amptek’s, and the Hubble line STScI’s.

## How many stages?

*Four questions*

The choice comes down to the load, and to whether the parts are already on the bench.

Key to a Peltier cooler

### How many stages?

1. 1a About 10 W or more on the cold face One stage, sized for the load
2. 1b A few watts or less Go to 2
3. 2a Buying one part Go to 3
4. 2b Building from two ordinary modules Go to 4
5. 3a A watt or more Two or three stages
6. 3b Under a watt Four stages, sealed from the air; five only for a few hundred milliwatts
7. 4a Two supplies About 5 V on top, 12 V under it: 19.5 °C colder than one module
8. 4b One 12 V supply Both in series: 5.6 °C colder than one module, on half the power

The watts are what sits on the cold face, from Fig. 41j, with the hot face held at 27 °C. A real heatsink runs warmer and moves every line up. Steps 4a and 4b are the two modules of Fig. 41a on its fan heatsink, with nothing on the cold face.

#### Conditions

- **Simulated:** Every temperature and wattage on this page comes from a model of the TEC1-12706 fitted to Thermonamic’s datasheet, and from stacks built out of it. None was measured on a bench.
- **Module:** TEC1-12706, 40 × 40 × 3.8 mm, 127 pairs of legs. The standard model of a module, with its Seebeck coefficient, resistance and thermal conductance each changing with temperature, fitted to the sheet’s ratings at 27 and 50 °C and to its charts. With its hot face held at 27 °C it gets 70.5 °C below it, against the sheet’s 70.
- **Material:** The sheet’s data stop near −8 °C, so below that the material follows the shape of Ferrotec’s published module curves, scaled to meet the fit.
- **Stacks:** Each stage is a module in the same model. The heat leaving one stage’s hot face enters the next stage’s cold face at the same temperature, with nothing between them.
- **Heatsink:** 0.30 °C per watt to a 25 °C room, with its fan. Nothing on the cold face, and no air reaching it, unless a line says otherwise.
- **Family:** Thermonamic’s TEC2 to TEC5 parts, each stage the 12706’s legs with the sheet’s count of pairs, and one leg size per part fitted so its best current lands on the sheet’s rated current. Hot face held at 27 °C, each part at its best current, never past its rated one.
- **Render:** Blender. The modules, heatsink and family follow their sheets’ sizes. The detector can is drawn for this page.

Fitted to datasheets. Nothing on this page has been measured on a bench.

#### Limits

- No air reaches the cold faces in the model. Let room air in, at 0.02 W per °C, and the fan-heatsink results warm by 1.5 to 3.3 °C: −27.7 °C, −27.2 °C and −45.3 °C.
- Stages touch with nothing between them. The grease and ceramic between two hand-stacked modules would cost a little more.
- Below about −8 °C the material rests on Ferrotec’s curves, not on the 12706’s sheet.
- Sheets print each stage’s pairs of legs but not their size, so the model gives every stage the 12706’s legs. Thermonamic’s TEC2-127-127-06, two stages of 127 pairs, is rated 93 °C, where two identical stages reach 71 °C in the model, so its stages must differ. Kryotherm’s four-stage part with the same pairs, 127, 71, 31 and 17, comes out 9 °C better in the model than on its sheet.
- Every part here runs at its best current. A real controller may hold a temperature at less.
- The five-stage part lifts 1.07 W at a 100 °C drop in the model, on 52 W, where its sheet reads about 1.14 W on about 50 W.

#### Files

- sim/tec.py The TEC1-12706 model and its fit to the datasheet
- sim/cascade.py The stacks: two modules at set voltages and at their best currents, the family, the voltage sweeps, the loads and the check against published parts
- render/stack.py The two rigs and the cut stack in Blender
- render/cascade.py The family and the four-stage part cut open
- render/uses.py The detector can

#### Sources

- [Thermonamic TEC1-12706 datasheet (a distributor’s copy): ratings at 27 and 50 °C, size and pairs of legs](https://dessy.ru/include/images/ware/pdf/RDKT0083.PDF)
- [Thermonamic multistage modules and datasheets: TEC2-127-71-042, TEC3-127-71-31-03, TEC4-127-71-31-17-03, TEC5-127-71-31-17-8-03 and TEC2-127-127-06, their pairs per stage, drops, currents, voltages and heats](https://www.thermonamic.com/product/1/5.html)
- [Kryotherm multistage coolers: the four-stage part with 127, 71, 31 and 17 pairs, and its rated drop](https://kryothermtec.com/multistage-thermoelectric-coolers.html)
- [Ferrotec Thermoelectric Technical Reference, section 11: the module curves used below −8 °C](https://thermal.ferrotec.com/technology/thermoelectric-reference-guide/thermalref11/)
- [TEC Microsystems, thermoelectric coolers FAQ: the drop lost in dry air, nitrogen, argon and xenon against a vacuum](https://www.tec-microsystems.com/faq/thermoelectric-coolers-faq.html)
- [Marlow MI6030 datasheet, 102-0056 Rev G: six stages, 133 °C in a vacuum with no load](http://web.archive.org/web/20040405021706/http://www.marlow.com:80/Products/DataSheets/MI6030.pdf)
- [Custom Thermoelectric, multistage modules, read 12 November 2026: the two-, four- and five-stage parts and prices](https://customthermoelectric.com/products/thermoelectric-coolers-tecs/multistage-tecs.html)
- [Custom Thermoelectric, single-stage modules, read 12 November 2026: the 40 mm 6 A module at $24.25](https://customthermoelectric.com/products/thermoelectric-coolers-tecs.html)
- [Amptek X-ray detector selection guide: two-stage coolers in vacuum-sealed TO-8 cans, and portable XRF](https://www.amptek.com/Products/x-ray-detectors-overview/x-ray-detector-selection-guide)
- [Amptek FAST SDD brochure: the 4.1 g detector module and its two-stage cooler](https://edge.sitecorecloud.io/ametekinc1236b-ametekb19a-productiondcfa-1d17/media/Project/Ametek/amptek/PDF/X-Ray/fast-sdd-70-mm2-detector-brochure-(1).pdf)
- [Thorlabs VML10T4 and VML10T0, read 12 November 2026: a four-stage cooled infrared detector at −78 °C and its uncooled twin, with prices](https://www.thorlabs.com/item/VML10T4)
- [STScI, WFC3 Instrument Handbook, section 5.5: the infrared detector held at 145 K by a six-stage cooler](https://hst-docs.stsci.edu/wfc3ihb/chapter-5-wfc3-detector-characteristics-and-performance/5-5-the-wfc3-ir-channel-detector)
- [Instructables, “Make a Cloud Chamber using Peltier Coolers”, 2010: a 12710 at 12 V under a 12709 at 5 V](https://www.instructables.com/Make-a-Cloud-Chamber-using-Peltier-Coolers/)
- [Instructables, “Peltier Cooled Cloud Chamber”: tracks only below about −25 °C](https://www.instructables.com/Peltier-Cooled-Cloud-Chamber/)

What should the next note be? [Ask for one](https://nearfieldnotes.com/#ask-for-a-note)

---

Source: https://nearfieldnotes.com/notes/peltier-stack/

Cite as: Michael Walker, “Peltier stacks”, Near Field Notes, Note 41, Rev 1, 15 Nov 2026. https://nearfieldnotes.com/notes/peltier-stack/

Figures: free to reuse under CC BY 4.0 (https://nearfieldnotes.com/license/). Each one's image is linked under its name. Credit Michael Walker, Near Field Notes, and link the figure: this address plus #fig- and its number, like https://nearfieldnotes.com/notes/peltier-stack/#fig-41a.